APlastic Bag
sales@aplasticbag.com877-992-2247APlasticBag.com 4023 Trail Creek Rd. Riverside, CA 92505

Vertical Double Foot Sealer

Vertical Double Foot Sealer - thumbnail view
Vertical Double Foot Sealer - icon view
Hover to rotate. Click to revert.

Vertical Double Foot Sealer

Secure your important packages and ensure the products inside remain fresh and intact using our double foot sealer. Ideal for vertical sealing, it provides perfect fixing irrespective of the type of products and packaging materials. In addition to offering efficient sealing, the sealer provides safety as well longevity. Easier to operate, it can be combined with a conveyor for effective filling of the carrier bags.
  • Works with a variety of items
  • Delivers quality seal
  • America’s no. 1 product
The Vertical Double Foot Sealer is ideal for packaging and sealing products that need vertical sealing, like packaging of heavy bags, liquids and powders. It can be difficult to lift heavy items for packaging and sealing which is where this sealer makes the task easy. You can combine it with a conveyor when it comes to filling up the package, while there is also a long stand that comes with it for additional flexibility as well.
  • Easy to operate
  • Makes a durable and tough seal that cannot easily unravel
  • Perfect sealer to use on heavier packaging
  • Safe to use

Additional Detail

Generally Ship 2-3 Business Days

General FAQs

  • Can I change 2mm seal width 5mm ?

    Can I change 2mm seal width 5mm ?

    Unfortunately, the answer is no. A 2mm and 5mm sealer utilize two different transformers and putting a 5mm heating element on a 2mm sealer could irreparably damage your sealer. Round wires and 2mm wires, however, are interchangeable.

  • What type of material can my sealer?

    What type of material can my sealer?

    Impulse sealers can instant seal a variety of poly materials including but not limited to: Polyethylene, Saran, Nylon, Polyvinylchloride, Polypropylene, Pliofilm, Kel-F, Mylar, Polyflex, Polyurethane, and Polyvinyl alcohol.

  • I notice that my sealer is arcing ?

    I notice that my sealer is arcing ?

    If you are experiencing arcing when you seal your material, most likely, you have worn out your element and PTFE adhesive and MUST replace them before you damage the timer.

  • My sealer is not sealing? What do I do?

    My sealer is not sealing? What do I do?

    The #1 most common issue is maintenance. If your sealer is not working, check to see if your element is broken and/or your PTFE adhesive has worn through. If the element comes into contact with the body of the sealer due to a worn adhesive, the element may have "shorted" and caused damage to the timer. If both elements and PTFE adhesives are good condition, we recommend taking a look at the microswitch (small unit that allows an electrical current to pass through when the arm is brought down) and the electronic timer (unit that controls the seal cycle duration.)

  • My impulse sealer is not sealing?

    My impulse sealer is not sealing?

    When you do not hear a "click click" when you bring the arm down to the base of the sealer, that is a sign that the microswitch is not activated and there is no electrical current being transferred. We suggest making some easy slight adjustments to the microswitch. Please UNPLUG the unit before making any adjustments

  • When do I change my element (heating wir

    When do I change my element (heating wir

    When the element breaks, it is time to change to a new element. If you change the element, we absolutely absolutely recommend changing the PTFE adhesive (bottom adhesive strip) found underneath the element. See our answer below for more information.

  • When do I change the PTFE cloth and adhe

    When do I change the PTFE cloth and adhe

    For the PTFE cover, we recommend changing the cover BEFORE it burns through. As the cover wears, you will see a discoloration where it comes into contact with the element, you may also notice that your element is sticking to the thermoplastic material you are sealing. You can maneuver the cover back and forth to allow the element to come into contact with the unused portions of the PTFE cover. For the PTFE adhesive, you must replace the bottom sealing strip whenever you change the element. The adhesive serves as a barrier between the heating element and the sealer's body. When the sealer's heating element has burned through the bottom adhesive and arc'ed on the sealer's body, the element will break as well as destroy the timer. When you replace your adhesive, make sure the adhesive is 1/4"-1/2" past the machine on both ends to prevent the heating element from coming into contact with the sealer's body.

Customer Reviews

Add-ons to Consider

Upper Teflon Cloth For Douple Impulse
Upper Teflon Cloth For Douple Impulse
Item #: AIE83
As low as: 9.00/1
5 options available.
Lower Teflon Cloth For Double Impulse
Lower Teflon Cloth For Double Impulse
Item #: AIE84
As low as: 53.80/1
5 options available.
Silicon Rubber For Double Impulse
Silicon Rubber For Double Impulse
Item #: AIE80
As low as: 11.80/1
4 options available.
Replacement Kits For Foot Sealer
Replacement Kits For Foot Sealer
Item #: AIE52
As low as: 25.80/1
9 options available.
Lower Teflon Cloth For Foot Sealer
Lower Teflon Cloth For Foot Sealer
Item #: AIE75
As low as: 35.60/1
3 options available.
Processing
Item is being added to cart